INTRODUCTION
To the owner or user: The service manual you are
reading is intended to provide you, and the
maintenance or service technician, with the
information needed to install, start up, clean,
maintain, and service this ice system.
The FME804R and NME654R are a remote
condenser modular ice systems that fit a variety of
Scotsman storage bins. Their features include:
front service for the freezer, gearmotor, control
box, water reservoir, and bin control; an electronic
control (AutoSentry) for monitoring ice and water
level; a thermostatic expansion valve; and HP62 as
the refrigerant.
NME654R & FME804R
January 2000
Page 1
Table of Contents
FOR THE INSTALLER · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 2
FOR THE INSTALLER · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 3
REMOTE CONDENSER SPECIFICATIONS · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 4
Remote Condenser Location · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 5
FOR THE INSTALLER: Remote Condenser · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 6
FOR THE INSTALLER: Coupling Instructions · · · · · · · · · · · · · · · · · · · · · · · · · · Page 7
FOR THE INSTALLER: Location · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 8
FOR THE PLUMBER · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 9
FOR THE ELECTRICIAN · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 10
FOR THE INSTALLER: Completed Installation · · · · · · · · · · · · · · · · · · · · · · · · · · Page 11
FOR THE INSTALLER: Final Check List · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 12
START UP · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 13
COMPONENT DESCRIPTION · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 14
COMPONENT DESCRIPTION: Control Box · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 15
ELECTRICAL SEQUENCE · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 16
OPERATION: Water · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 17
OPERATION: Refrigeration · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 18
OPERATION: Refrigeration · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 19
OPERATION: Refrigeration · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 20
CLEANING & SANITIZING · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 21
SENSOR MAINTENANCE · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 22
BEARING MAINTENANCE · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 23
AUGER AND OTHER MAINTENANCE · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 24
OPERATING CHARACTERISTICS · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 25
SERVICE DIAGNOSIS: · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 26
SERVICE DIAGNOSIS: · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 27
CONTROL SYSTEM DIAGNOSTICS · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 28
REMOVAL AND REPLACEMENT: Water Reservoir & Bin Controls · · · · · · · · · · · · · · · Page 29
REMOVAL AND REPLACEMENT: Bearing And Breaker · · · · · · · · · · · · · · · · · · · · Page 30
REMOVAL AND REPLACEMENT: Auger · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 31
REMOVAL AND REPLACEMENT: Water Seal · · · · · · · · · · · · · · · · · · · · · · · · · · Page 32
REMOVAL AND REPLACEMENT: Evaporator · · · · · · · · · · · · · · · · · · · · · · · · · · Page 33
REMOVAL AND REPLACEMENT: Gearmotor Assembly · · · · · · · · · · · · · · · · · · · · Page 34
REFRIGERATION SERVICE · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · Page 35
Note this symbol when it appears.
It is an alert for important safety
information on a potential hazard.
Vista de página 0
1 2 3 4 5 6 ... 34 35

Resumo do Conteúdo

Página 1 - NME654R & FME804R

INTRODUCTIONTo the owner or user: The service manual you arereading is intended to provide you, and themaintenance or service technician, with theinfo

Página 2

FOR THE ELECTRICIANCONFORM TO ALL APPLICABLE CODESConnect the electrical power to the unit to the wiresin the junction box at the rear of the machine.

Página 3

NME654R & FME804RJanuary 2000Page 11FOR THE INSTALLER: Completed InstallationROOFCUT-AWAYINSULATEDPRECHARGEDREFRIGERANTTUBINGA typical installatio

Página 4

FOR THE INSTALLER: Final Check List1. Is the ice system installedindoors in a location where the airand water temperatures arecontrolled, and where th

Página 5

INITIAL START UPPre-Start Inspection1. Remove the front, left, and right side servicepanels.2. Check that any styrofoam shipping blocks havebeen remov

Página 6

COMPONENT DESCRIPTIONControl Box: Contains the electrical controls thatoperate the machine.High Pressure Cut Out: An automatic resetswitch sensing the

Página 7

COMPONENT DESCRIPTION: Control BoxContactor: A definite purpose contactorconnecting the compressor and the remotecondenser fan motor to the power supp

Página 8

There are 7 indicator lights on the control board:·WTR-OK (Water OK). Green. Normal =Glowing. Glows when there is water in thereservoir.·PWR-OK (Power

Página 9

OPERATION: WaterWater enters the machine through the 3/8" maleflare at the rear of the cabinet, goes to the waterreservoir which it enters throug

Página 10

OPERATION: RefrigerationBeginning at the compressor, the refrigerant iscompressed into a high temperature gas. Thedischarge line directs this gas to t

Página 11

OPERATION: RefrigerationLow Condensing TemperatureThe refrigeration system under low condenser airtemperatures is much the same as it is underhigher t

Página 12

FOR THE INSTALLERThese machines are designed to fit thefollowing Scotsman storage bins:·SB480 and extensions (with bin topKBT18)·HTB555 or BH550 using

Página 13

OPERATION: RefrigerationPUMP DOWNDuring the pump down cycle (usually initiated bythe circuit board de-energizing the liquid line valve)the discharge g

Página 14

CLEANING & SANITIZINGA Scotsman Ice System represents a sizable investment of time and money in any company’s business. Inorder to receive the bes

Página 15

1. The bin control uses devices that sense light,therefore they must be kept clean enough so thatthey can “see”. At least twice a year, remove thebin

Página 16

BEARING MAINTENANCEThe bearing in the breaker should also be checkedat least two times per year.A. Check the bearing by:·removing the ice chute cover·

Página 17

AUGER AND OTHER MAINTENANCEIn some areas the water supply to the icemaker willhave a great deal of minerals in it, and that willresult in an evaporato

Página 18

NME654R & FME804RJanuary 2000Page 25OPERATING CHARACTERISTICSTypical Low Side Pressure·28 - 32 PSIGTypical Discharge Side Pressure·240 PSIG, will

Página 19

NME654R & FME804RJanuary 2000Page 26SERVICE DIAGNOSIS:Symptom Possible Cause Probable CorrectionNo ice is made, nothing operates Unit off due to n

Página 20

NME654R & FME804RJanuary 2000Page 27No ice, auger motor is turning Compressor contactor coil is open Check / replace contactorCompressor will not

Página 21

CONTROL SYSTEM DIAGNOSTICSThe control system consists of:·Control Board·Water Sensor·Ice Sensors·High Pressure Cut Out·Low Pressure Cut OutIf the unit

Página 22

WATER RESERVOIR1. Shut off the water supply to the icemaker.2. Remove front panel and reservoir cover.3. To remove float only, disconnect water inletc

Página 23

FOR THE INSTALLERInstallation Limitations:This ice system is designed to be installed indoors,in a controlled environment:Min. Max.Air Temperature 500

Página 24

REMOVAL AND REPLACEMENT: Bearing And BreakerNote: Removal of the auger, water seal, evaporatorand gearmotor must begin at the top of theassembly.To Re

Página 25

To Remove the Auger:Turn off the water to the machine, and unclip theevaporator drain hose, pull it down and drain theevaporator into the bin or a con

Página 26

To Remove the Water Seal:(Assuming all steps to remove the auger havebeen performed.)1. The gearmotor/evaporator assembly will have tobe pulled away f

Página 27

To Replace the Evaporator:(Assuming all the steps for removal of the thrustbearing, breaker, auger, and water seal have beenperformed.)1. Discharge an

Página 28

To Remove and Repair the GearmotorAssembly:(Assuming that the procedures through removal ofthe water seal have been performed.)1. Remove the electrica

Página 29

NME654R & FME804RJanuary 2000Page 35CHARGINGCYLINDER orSCALERECEIVERSERVICE PORTREFRIGERATION SERVICEGeneral Information:Work on the refrigeration

Página 30

NME654R & FME804RJanuary 2000Page 4REMOTE CONDENSER SPECIFICATIONSRTE25 Precharged line set, 25’, R-404ARTE40. Precharged line set, 40’, R-404AICE

Página 31

Remote Condenser LocationUse the following for planning the placement ofthe condenser relative to the ice machineLocation Limits - condenser location

Página 32

FOR THE INSTALLER: Remote CondenserLocationLimited to a 40 foot or a 25 foot length ofprecharged refrigerant tubing connecting the icemachine to the r

Página 33

Initial Connections:1. Remove the protector caps and plugs. Wipe theseats and threaded surfaces with a clean cloth tobe certain that no foreign matter

Página 34

NME654R & FME804RJanuary 2000Page 8FOR THE INSTALLER: LocationTYPICAL INSTALLATIONREMOTECONDENSEREXCESSPRECHARGEDTUBING INSIDEBUILDINGIce MachineS

Página 35

FOR THE PLUMBERCONFORM TO ALL APPLICABLE CODESWater InletThe recommended water supply iscold water. Use 3/8" O.D. coppertubing, connect to the 3/