12
91773
The ice portion control has five modes to allow adjustment of the ice portions and for normal operation they are
as follows:
MODE INDICATOR STATUS
Normal operation Green
Cleaning mode Red/Amber flashing
Normal ice portion adjustment Amber
Extra ice portion adjustment Red
Agitation refill time adjustment Amber flashing
The control will return to Normal Operation Mode (green indicator) automatically if a button has not been oper-
ated for a period of one minute whenever one of the three adjustment modes have been accessed.
NORMAL OPERATION
To dispense ice, hold a cup directly under the ice chute, then press the appropriate size button on the ice por-
tion control. To obtain a full cup of ice, press the increase button followed by the appropriate size button. The ice
portion control will not dispense ice and will display a flashing green indicator light if sufficient ice is not available
in the ice chute to dispense the selected size. The indicator light will return to solid green and ice dispensing will
resume after the ice chute has been refilled.
The amount of ice dispensed for each size is changed in the Normal and Extra Ice Adjustment Modes. To ac-
cess the adjustment modes, press the decrease and increase buttons at the same time. The control will ad-
vance to the next mode in the sequence as shown in the table above and the indicator light will change to identi-
fy which mode is currently active.
CLEAN MODE
Access this mode when cleaning the ice chute. Refer to Cleaning Instructions on page 12.
NORMAL ICE PORTION ADJUSTMENT
From the Normal Operation Mode (green indicator), press both the decrease and increase buttons at the same
time twice. The amber indicator verifies that the normal portion adjustment mode has been accessed.
To change the amount of ice dispensed, press and hold down the size button for the desired size to be
changed. While holding the size button, press the decrease or increase button to decrease/increase the ice por-
tion size. The amber indicator turns off briefly each time the decrease or increase button is pressed. When the
minimum ice portion adjustment has been reached, the indicator will flash at a slow rate; at the maximum ad-
justment, the indicator will flash at a fast rate. After releasing the size button, the indicator light will flash green
for five seconds. During this time period, a sample can be obtained to check the portion size by pressing the
size key. The indicator light will return to amber (normal portion adjustment mode) after the sample is d
The indicator light will flash red after dispensing a sample, if an open circuit exists in the ice gate cylinder switch
wiring to the ice portion control of if an ice gate binding condition occurred during the sample. The indicator light
will display solid red briefly after a sample is dispensed if the ice gate cylinder switch was shorted.
To return to Normal Operation, press the decrease and increase buttons at the same time, twice.
EXTRA ICE PORTION ADJUSTMENT
The adjustment of Extra Ice Portions is accomplished in the same manner as Normal Ice Portions, except the
indicator light displays red. To access this mode, press both the decrease and increase buttons simultaneously
three time from the Normal Operation Mode (green indicator). The indicator will display red.
AGITATION REFILL TIME ADJUSTMENT
To adjust the amount of ice chute refill agitation, begin by accessing the Extra Ice Portion Adjustment Mode (red
indicator). Next, press and hold for the decrease and increase buttons for three seconds until the indicator
flashes amber. The indicator will flash up to four times; one flash corresponds to the minimum amount of refill
agitation and four flashes corresponds to the maximum amount of refill agitation. Change the amount of refill
agitation buy pressing one of the four size buttons -- -- the small button representing the minimum amount of
refill agitation. Increase the amount of refill agitation if the ice chute does not refill properly after dispensing ice.
To return to Normal Operation Mode, press the decrease and increase buttons at the same time.