Diagnostic Mode
Do not continue with the diagnosis of the ice maker if a fuse is blown, a circuit breaker is tripped, or if
there is less than a 120 volt power supply at the wall outlet. Units that failed during the first few days of
use should be checked for loose connections or miswiring.
Entering and Navigating — Manual Diagnostics
Turn the product to On. Within 10 seconds of Power On, press and hold the On and the Clean buttons.
Release both buttons when all user interface LEDs begin to flash.
Within 5 seconds of all LEDs flashing, push any other button (On, Off, or Clean). This begins manual
diagnostics. If no button is pressed within 5 seconds, the product goes into an automatic diagnostic
mode. Each component is cycled for 5 seconds.
The Off button is used to advance through each step. To exit manual diagnostics, press the On button.
After pressing any button to enter manual diagnostics all LEDs will illuminate for 5 seconds. The controls
will then automatically move to the first component.
Order
Component
On LED Off LED Clean LED
1 Entry into Test Mode ON ON ON
2
Bin Thermistor
ON Solid—OK. 2
blinks—Open. 4
blinks—Shorted.
OFF OFF
3
Evaporator Thermistor OFF OFF
ON Solid—OK
2blinks—Open
4blinks—Short
4a
Water Valve 4 min time
out Off button press will
advance to step 6
OFF
ON Solid—reservoir full
Blinking—reservoir empty
ON
4b Water Level Sensor OFF
ON Solid—reservoir full
Blinking—reservoir empty
ON
5 Water Pump ON ON ON
6 Reservoir Drain Pump ON OFF OFF
7
Compressor and
Condenser Fan Motor
ON Solid while
cooling
Blinking when evap
thermistor reaches 4.5ºF;
full frost pattern should be
visible
ON
8
Compressor and Hot
Gas Valve
ON Solid while
heating
ON Solid while heating
Blinking when evap
thermistor reaches 52ºF
ON Solid while
heating
9 None Off Off On is normal*
10 Ice Thickness OFF
2 Blinks—Thin. 4 Blinks
—Normal. 6 Blinks —Thick.
Press Clean button to cycle
between settings
OFF
July 2007
Page 11
CS0415
Service Manual